GTS-1309488 ACTIVE BUY

Supply Of Procurement Of Iv Cannula With Injection Port 20g. Spec: 1.disposable, Sterile, Single-use, Individually Transparent Packing. 2.a)size - 20 G, B)effective Length 19 - 50mm, C) Colour Code According To Size, D) Minimum Flow Rate 60 Ml/min. 3. Should Have An Injection Port, Snap Lid On Port, Leak-proof, Must Be Leur Fitting ,must Have Adaptable Fixation Wings. 4. Catheter Material A) Biocompatible Thermoplastic Polymer, Polyurethane-based (pur), Exhibiting Temperature- Responsive Softening At 37%b0c (%b1 2%b0c) To Reduce Vessel Trauma During Indwelling Use.b) Plain Pvc Catheters, Or Catheters Not Meeting The Kink-resistance Criteria Shall Not Be Accepted.c) Manufacturer's Material Datasheet And Independent Biocompatibility Test Report (iso 10993 Series) Must Be Submitted With The Technical Bid. 5. Kink Resistant. A)the Catheter Shall Withstand A 90%b0 Bend At A Radius Of %u226410 Mm Without Complete Lumen Occlusion. B) On Release Of The Induced Bend, Flow Shall Be Restored To %u226590% Of Nominal Unobstructed Flow Rate. C) Compliance Shall Be Demonstrated Via Test Report Per Astm F2343 Or An Equivalent Internationally Recognised Method, From An Independent/accredited Laboratory Or The Manufacturer's Certified In-house Lab With Nabl/iso 17025 Accreditation ,6. Should Be Non-thrombogenic, Non-toxic And Non-pyrogenic, Haemo And Thermocompatible.7. Needle:a). Stainless Steel Needle With Tri-bevel (or Equivalent Ultra-sharp) Point For Smooth, Low-resistance First-pass Insertion.b) Silicone Coating On The Needle Surface To Reduce Insertion Friction And Patient Discomfort Will Be Preferred.8. Flashback Chamber:a) Transparent Primary Flashback Chamber For Immediate Visual Confirmation Of Venous Access.b) Secondary Flashback Confirmation (visible Through The Catheter Hub/along The Catheter) Is Required For Reliable Placement Verification, Particularly In Low-flow Or Hypotensive Patients.9. Cannula Should Be: A). Thin-walled. B). X - Ray/radio-opaque Line For Determination By X-ray. ]

Eastern Railway
ID GTS-1309488
Estimated Value
Refer Document
Closing Date
18 Aug 2026
12 Days Left
Location
WEST BENGAL
HOWRAH
Overview
Supply Of Procurement Of Iv Cannula With Injection Port 20g. Spec: 1.disposable, Sterile, Single-use, Individually Transparent Packing. 2.a)size - 20 G, B)effective Length 19 - 50mm, C) Colour Code According To Size, D) Minimum Flow Rate 60 Ml/min. 3. Should Have An Injection Port, Snap Lid On Port, Leak-proof, Must Be Leur Fitting ,must Have Adaptable Fixation Wings. 4. Catheter Material A) Biocompatible Thermoplastic Polymer, Polyurethane-based (pur), Exhibiting Temperature- Responsive Softening At 37%b0c (%b1 2%b0c) To Reduce Vessel Trauma During Indwelling Use.b) Plain Pvc Catheters, Or Catheters Not Meeting The Kink-resistance Criteria Shall Not Be Accepted.c) Manufacturer's Material Datasheet And Independent Biocompatibility Test Report (iso 10993 Series) Must Be Submitted With The Technical Bid. 5. Kink Resistant. A)the Catheter Shall Withstand A 90%b0 Bend At A Radius Of %u226410 Mm Without Complete Lumen Occlusion. B) On Release Of The Induced Bend, Flow Shall Be Restored To %u226590% Of Nominal Unobstructed Flow Rate. C) Compliance Shall Be Demonstrated Via Test Report Per Astm F2343 Or An Equivalent Internationally Recognised Method, From An Independent/accredited Laboratory Or The Manufacturer's Certified In-house Lab With Nabl/iso 17025 Accreditation ,6. Should Be Non-thrombogenic, Non-toxic And Non-pyrogenic, Haemo And Thermocompatible.7. Needle:a). Stainless Steel Needle With Tri-bevel (or Equivalent Ultra-sharp) Point For Smooth, Low-resistance First-pass Insertion.b) Silicone Coating On The Needle Surface To Reduce Insertion Friction And Patient Discomfort Will Be Preferred.8. Flashback Chamber:a) Transparent Primary Flashback Chamber For Immediate Visual Confirmation Of Venous Access.b) Secondary Flashback Confirmation (visible Through The Catheter Hub/along The Catheter) Is Required For Reliable Placement Verification, Particularly In Low-flow Or Hypotensive Patients.9. Cannula Should Be: A). Thin-walled. B). X - Ray/radio-opaque Line For Determination By X-ray. ] Delivery/work location: Howrah, West Bengal. This is a Limited tender. Bid closing date: 18-08-2026.
Tender Information
Tender No GTS-1309488 Tender Type Limited
Contract Type Buy Category Buy
Offer Validity EMD Required ₹0
Document Cost ₹0 Submission Time 13:30:00
Timeline
Published
04 Aug 2026
Bid Closing
18 Aug 2026
13:30:00
Issuing Authority
Organisation
Eastern Railway
Department ID
13
WEST BENGAL , HOWRAH
Fees & EMD
EMD Amount ₹0
Tender Fee ₹0
Offer Validity
🔒

Get Document Access

Fill in your details — we'll contact you within 12 hours

📄 Tender Document Request

🔒 Free · No spam · Response within 12 hours

— or —
Already have an account? Login to access instantly